What permeance must a vapour barrier have under Ontario's Code?
What permeance must a vapour barrier have under Ontario's Code?
Ontario's Building Code sets the vapour barrier permeance limit in clause 9.25.4: the barrier must have a permeance no higher than 60 ng/(Pa·s·m²), and it must be placed on the warm side of the insulated assembly.
That rule applies to insulated walls, ceilings and floors that separate heated space from unheated space, outside air or the ground. The vapour barrier can be a separate sheet product, or the insulation itself can serve as the vapour barrier, provided the insulation is thick enough that its permeance meets the 60 ng/(Pa·s·m²) limit.
A few things follow from that rule that are worth confirming with your contractor. First, a separate set of rules covers the air barrier, which is continuous: clause 9.25.3 requires that penetrations be sealed, and that joints in flexible sheet barriers be sealed with tape or sealant, or lapped at least 100 mm and clamped. Access hatches and sump pit covers in an air-barrier assembly must be weatherstripped. Second, the warm-side placement rule means the barrier goes between the insulation and the interior living space, not on the cold side of the assembly. Third, where insulation is used as the vapour barrier, ask the contractor to confirm in writing which product they are specifying and how they are calculating that it meets the permeance limit.
A few questions worth putting to your contractor before work begins:
- What product are they using as the vapour barrier, and what is its rated permeance?
- If the insulation itself is serving as the vapour barrier, what thickness are they specifying, and how does that meet the 60 ng/(Pa·s·m²) limit?
- How will penetrations (electrical boxes, pipes, any structural members passing through) be sealed, and with what materials?
- Will the vapour barrier be covered by an interior finish, and if so, what?
Make sure the written contract spells out the vapour barrier product by name, its permeance rating, where it goes in the assembly, how penetrations will be sealed, and the completion date, so there is no ambiguity once the walls are closed.
Want this done at your place?
Tell us which part of the house you want insulated and we'll send it to local Ottawa insulation contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.
R-Value IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.
Ready to Get Quotes?
Find local insulation contractors in Ottawa. Free matching, no obligation.