Is a cathedral ceiling insulated differently from an attic in Ottawa?

Question

Is a cathedral ceiling insulated differently from an attic in Ottawa?

Answer from R-Value IQ

Yes. A cathedral ceiling has no open attic space: the insulation sits inside the roof assembly itself, between the ceiling finish below and the roof sheathing above, and the Code's venting rules apply inside that assembly.

Ontario's Building Code (Section 9.19) says that where insulation sits between a ceiling and the roof sheathing, there must be a continuous air space between the top of the insulation and the sheathing, plus vents placed so that at least 25 per cent of the vent area is at the top and at least 25 per cent at the bottom, spread on opposite sides. Where venting is provided to a roof-joist space, at least 63 mm of space is kept above the insulation, and where preformed baffles are used, they keep an air space of at least 25 mm and extend at least 50 mm above the top of the insulation. The insulation must not restrict the free flow of air through that space.

If a contractor proposes an unvented, spray-foamed roof instead, Natural Resources Canada advises: do not proceed without approval from your building inspector, and then only use a certified spray foam contractor who is familiar with the process. The Code (9.25.2.5.(1)) also says spray-applied polyurethane insulation shall be installed in accordance with CAN/ULC-S705.2, so ask any spray foam contractor for proof that their work meets that standard.

For a new house or addition, the Code's energy standard for housing, SB-12, sets the minimum for a ceiling without an attic space at R-31 (Zone 1, which covers all of Ottawa). That is the new-construction target; we found no Code number that applies to voluntarily upgrading an existing cathedral ceiling.

A quote for cathedral ceiling work should spell out the material, the finished thickness, the R-value achieved, how the required air space will be kept or, for an unvented design, the approval from your building inspector, and what air and vapour barrier work is included. If spray foam is proposed, ask for the contractor's written instructions on when to leave the area and how long to keep it ventilated.

If you want to hear from Ottawa insulation contractors who work on cathedral ceilings, the request form on this page sends your details to contractors listed in the Ottawa Construction Network directory.

Ottawa Insulation Contractors

Want this done at your place?

Tell us which part of the house you want insulated and we'll send it to local Ottawa insulation contractors, who reply by email. We send it out to local contractors for you. Free, no pressure.

Fields marked are required.

We won't call you. There's no phone box above because we don't ask for one — your estimate comes by email, on your time.

Request received We’ve sent your details to local Ottawa insulation contractors. Interested contractors reply by email. A confirmation is on its way to your inbox.

R-Value IQ -- Built from the Ontario Building Code, Ontario regulations and City of Ottawa sources and real construction experience. Answers are for informational purposes only and are not a professional assessment.

Ready to Get Quotes?

Find local insulation contractors in Ottawa. Free matching, no obligation.

Find an Insulation Contractor