For walls opened to the studs in a new house or addition, Ontario's energy standard for housing, SB-12, sets the minimum at R-22 for above-grade walls in Zone 1, which covers Ottawa. For new houses, other SB-12 packages allow R-19 plus R-5 continuous insulation, or R-14 plus R-7.5 continuous insulation. Those values apply to new construction and additions only.
For an existing house being renovated, Ontario's Building Code takes a different approach. Section 11.3.1.1.(1) says that where an existing building system is materially altered or repaired, its performance afterward must be at least equal to its performance before the work. We found no Code number for walls in an existing home like the one SB-12 sets for new construction. Compliance alternative C207 also allows lesser amounts of insulation and vapour barrier where framing is being altered to match the existing framing.
What goes into the cavity depends on the material you and the contractor choose. Natural Resources Canada design values per inch are: glass fibre batt R-3.2, mineral fibre batt R-3.4, blown mineral fibre R-3, open-cell spray foam R-3.6, closed-cell spray foam R-6. The Code's note on insulating existing wood-frame walls says adding insulation increases the likelihood of damage to framing and cladding from moisture accumulation, and suggests sealing openings, coating the inside surface with a low-permeability paint, and checking and repairing the siding, flashing and caulking before the work is done.
The Code also asks for a vapour barrier on the warm side of the assembly and a continuous air barrier. Where insulation serves as the vapour barrier, it must be thick enough to meet that permeance limit. For spray-applied polyurethane foam, the Code states it must be installed in accordance with CAN/ULC-S705.2, the standard that sets installer requirements, so ask any spray foam contractor for proof they meet it.
A few things to ask before the work starts: whether the quote covers air sealing at all penetrations and at the top and bottom plates; what vapour barrier product is being used and where it sits in the assembly; and whether the siding, flashing and caulking will be checked before the walls are closed.
When you have two written quotes side by side, line up the material named, the total wall area in square feet, and the finished thickness and resulting R-value each contractor is promising, so you are comparing the same scope rather than the same price.
Related service: Batt Insulation in Open Walls What it costs: Existing walls